top of page

iOlab

IMG_1006.jpg

Siamo rivenditori ufficiali di iOlab un carrellino per eseguire diversi esperimenti di fisica prodotto da MacMillan Learning, che coprono diversi argomenti affrontati alle scuole secondarie di II grado.

​

Discover the innovative technology of iOlab, a built in sensors measure force, acceleration, velocity, displacement, magnetic field, rotation, light, sound, temperature, pressure, and voltages down to a few μV. Expansion connectors provide access to over a dozen user controllable digital and analog inputs and outputs. Free software controls the device, acquires and displays data in real time, and provides a suite of analysis and data manipulation features.

iOLab system overview

• Wireless IOLab unit communicates with USB dongle using 2.4GHz ISM band.
• Powered by 2xAA batteries.
• TI-MSP430F5329 microcontroller, TI-CC2543 radio.
• Dongle communicates with PC/Mac via simple virtual comport interface (i.e. no special USB
programming required).
• Individual sensors synchronized and read out in various predefined configurations.
• Up to 4.8 kHz sensor sampling.
• One dongle can synchronously read data from two IOLab remotes.
• Wireless range up to 100 feet. RSSI included in data.
• Size 30 mm x 75 mm x 130 mm, Weight: Remote 148 g (w/o batteries), Dongle 8 g.
• Force probe thread: M3

Sensor parameters

3D accelerometer (14 bit signed, 2/4/8g ranges, 1.56-800 Hz sample rate)
• 3D magnetometer (16 bit signed, 1000 uT range, 0.63-80 Hz sample rate)
• 3D gyroscope (16 bit signed, measures ωX, ωY, ωZ, 250/500/2000 deg/sec ranges,
95-760 Hz sample rate).
• Rolls on 3 wheels along Y-axis; optical encoder measures displacement velocity & acceleration, 1 mm/count, 100
Hz sample rate.
• Force probe (Range ± 10 N parallel to Y axis, 12 bit signed, up to 4.8 kHz sample rate)
• Light intensity sensor (12 bit, up to 4.8 kHz Hz sample rate)
• Atmospheric pressure sensor (0.15 kPa resolution, 1-100 Hz sample rate)
• Temperature sensor (die temperature, w/ 400 Hz over-sampling).
• Microphone (12 bit, 20-20kHz, up to 4.8 kHz Hz sample rate).
• Speaker/Buzzer (programmable pitch & duty cycle, 35Hz – 8.4 kHz)
• EKG daughter board mates with header (3 or 6 differential channels + ground ref, each 12 bits, TI-INA333
instrumentation amplifiers, up to 800 Hz sample rate).
• DC coupled high gain differential amplifier (gain = 1,400, f3dB = 100Hz), up to 4.8 kHz sampling.
• 6 analog input pins on header (sampled by 12 bit ADC at up to 4.8 kHz).
• 6 digital I/O pins on header.
• DAC output on header (8 bit resolution).
• Two pushbuttons (software readable).
• Two tri-color LED’s.
• FTDI interface on header (standard configuration).
• Over the air re-programming of both sensor microcontrollers (i.e. no special hardware needed to redesign &
modify the open source firmware).
• Device designed to be opened; threaded metal bushings for all screws; easy to disassemble and reassemble.

Software

Free download and info at www.iolab.sciance.
• No installation required – runs from application folder which can be anywhere (including thumb-drive).
• Runs without internet access.

Discover how to get started on the iOLab dedicated site: iolab.science

bottom of page