top of page

iOlab

IMG_1006.jpg

Siamo rivenditori ufficiali di iOlab un carrellino per eseguire diversi esperimenti di fisica prodotto da MacMillan Learning, che coprono diversi argomenti affrontati alle scuole secondarie di II grado.

Discover the innovative technology of iOlab, a built in sensors measure force, acceleration, velocity, displacement, magnetic field, rotation, light, sound, temperature, pressure, and voltages down to a few μV. Expansion connectors provide access to over a dozen user controllable digital and analog inputs and outputs. Free software controls the device, acquires and displays data in real time, and provides a suite of analysis and data manipulation features.

iOLab system overview

• Wireless IOLab unit communicates with USB dongle using 2.4GHz ISM band.
• Powered by 2xAA batteries.
• TI-MSP430F5329 microcontroller, TI-CC2543 radio.
• Dongle communicates with PC/Mac via simple virtual comport interface (i.e. no special USB
programming required).
• Individual sensors synchronized and read out in various predefined configurations.
• Up to 4.8 kHz sensor sampling.
• One dongle can synchronously read data from two IOLab remotes.
• Wireless range up to 100 feet. RSSI included in data.
• Size 30 mm x 75 mm x 130 mm, Weight: Remote 148 g (w/o batteries), Dongle 8 g.
• Force probe thread: M3

Sensor parameters

3D accelerometer (14 bit signed, 2/4/8g ranges, 1.56-800 Hz sample rate)
• 3D magnetometer (16 bit signed, 1000 uT range, 0.63-80 Hz sample rate)
• 3D gyroscope (16 bit signed, measures ωX, ωY, ωZ, 250/500/2000 deg/sec ranges,
95-760 Hz sample rate).
• Rolls on 3 wheels along Y-axis; optical encoder measures displacement velocity & acceleration, 1 mm/count, 100
Hz sample rate.
• Force probe (Range ± 10 N parallel to Y axis, 12 bit signed, up to 4.8 kHz sample rate)
• Light intensity sensor (12 bit, up to 4.8 kHz Hz sample rate)
• Atmospheric pressure sensor (0.15 kPa resolution, 1-100 Hz sample rate)
• Temperature sensor (die temperature, w/ 400 Hz over-sampling).
• Microphone (12 bit, 20-20kHz, up to 4.8 kHz Hz sample rate).
• Speaker/Buzzer (programmable pitch & duty cycle, 35Hz – 8.4 kHz)
• EKG daughter board mates with header (3 or 6 differential channels + ground ref, each 12 bits, TI-INA333
instrumentation amplifiers, up to 800 Hz sample rate).
• DC coupled high gain differential amplifier (gain = 1,400, f3dB = 100Hz), up to 4.8 kHz sampling.
• 6 analog input pins on header (sampled by 12 bit ADC at up to 4.8 kHz).
• 6 digital I/O pins on header.
• DAC output on header (8 bit resolution).
• Two pushbuttons (software readable).
• Two tri-color LED’s.
• FTDI interface on header (standard configuration).
• Over the air re-programming of both sensor microcontrollers (i.e. no special hardware needed to redesign &
modify the open source firmware).
• Device designed to be opened; threaded metal bushings for all screws; easy to disassemble and reassemble.

Software

Free download and info at www.iolab.sciance.
• No installation required – runs from application folder which can be anywhere (including thumb-drive).
• Runs without internet access.

Discover how to get started on the iOLab dedicated site: iolab.science